This paper provides an acoustic characterization of the Theater Diogo Bernardes (Ponte de Lima, Portugal). The main results of the measured acoustic parameters were: LAeq(HVAC) at 26 dB, Speech Transmission Index ranging from 0.56 to 0.71, Reverberation Time (avg 500-1k Hz) of 0.99 s, C80 (avg 500-1k Hz) of 4.7 dB, D50 avg 500-1k Hz) of 0.59, and Center Time (avg 500-1k Hz) of 63 ms. A comparison is made with 19 Portuguese halls and five international horseshoe-type theaters.